![]() What this process does is to write the desired home position value to the absolute encoder within the motor so that even after a power cycle the home position is remembered. (note: Wait a minimum of 1 second after clicking the write icon before power cycling the drive) Disconnect from the drive with SoMove using the disconnect Icon and then power cycle the drive. In the "Direct access" section enter modbus address of 1324 ( ENC1_adjustment ) and then populate the preferred position value that you want your home position to be, from step 3,into the RAW value field of the Direct access section.Ĩ. 3 Sonus Faber Guarneri Tradition, acoustic crossover on tweeter axis at 50, corrected for microphone response, with nearfield responses of woofer (blue) and. In the User level pull-down choose "Expert" then enter the password of 696969 and then click OKĦ. Change the user access level of SoMove to Expert by navigating to Device > User level > Set user level. Make sure to check it out Amarra Symphony: Amarra Symphony with IRC is an advanced music file player for the Apple Mac platform. This very powerful Mac only software is now fully integrating import of UMIK-1 calibration file and automatic SPL calibration. Using SoMove initiate a homing method of your choice to bring the load to your preferred home position.Ĥ. Fuzz Measure Pro v4: Fuzz measure is no stranger to acoustic measurements. The absolute value of a variable x is represented by x which is pronounced as Mod x or Modulus of x. Learn Absolute Value from a handpicked tutor in LIVE 1-to-1 classes. Connect to the drive using SoMove commissioning toolģ. To find the absolute value of a real number, we consider only the number and remove the sign. Mount the motor and connect the motor output shaft to the load.Ģ. ![]() The value of that reference position is then written to the absolute encoder by entering SoMove in expect mode and writing the reference position to the absolute encoder.ġ. Once the motor is installed and physically attached to the load the position of the load should be brought to a known reference position. Here is an basic overview of the process. The process is simple and can be done using SoMove commissioning software. We illustrate how to perform calibration tests on a thick plate and how to implement two different mechanical calibration sources: ball impact and glass capillary fracture. Customers should make note that the position of a motor with an Absolute Encoder must be calibrated during initial set-up of the machine and any time the motor has been removed or replaced. ularly useful for obtaining absolute measurements of AE wave amplitude and shape, which can be used to constrain the physics and mechanics of the AE source.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |